Home > Dos Error > Dos Error 162 Hardware Failure

Dos Error 162 Hardware Failure

Contents

Outside possible range of values. 202 Stack overflow error. DOS never allows more than 15 open files per process. Resolution: Check for number too large. 206 Floating point underflow. PRINT and PLOT operations are considered to be I/O procedures, and when you change graphics modes you are in fact OPENing a channel to the screen handler. http://sammcallister.com/dos-error/dos-error-4-xp.html

Note: The manual fix of Dos Cmd Set Errorlevelerror is Only recommended for advanced computer users.Download the automatic repair toolinstead. Reported by Erase if the name assigned to the file variable specifies a directory or a read-only file. CIO searches the table for the appropriate device, but if the handler is not present in the table error 130 is returned. UNIX 60=Device not a stream.

Dos Error Codes

Although the wildcard characters are legal, they are not so when creating a file, only when reading from an already existing one. DOS 101=Disk full. Moral: always have a ready formatted spare disk or two to hand. Error 168 occurs if the device concerned does have special command codes, but the code you used is not recognised by the handler.

COBOL 14=Sequential access to relative file. If it occurs and you haven't been tampering with the disk structure, your drive may need servicing. Reported by Reset or Append if FileMode allows writing and the name assigned to the file variable specifies a directory or a read-only file. Dos Error 3 Others (the non-resident handlers) are either booted in (such as Disk or RS232-C handlers) or can be added later.

UNIX 23=File table overflow. Dos Error Codes List A fault code of 00 indicates that no problem was found. A read error occurred in FIPRO.OVR. http://porthos.ist.utl.pt/docs/fpc/user/node46.html See error 164 for a description of the POINT statement.

UNIX 118=Protocol not available. Dbfntx/1001 DOS 104=Not open for input. the heap will try to allocate more memory if needed. Check the syntax of the command passed to the device.

Dos Error Codes List

DOS 5=Access denied. https://groups.google.com/d/topic/comp.os.msdos.misc/3fACst8uMSo Note that, if you have initialization code in any of your overlaid units, you MUST create an additional non-overlaid unit which calls OvrInit, and use that unit before any of the Dos Error Codes The meaning of the error codes related to POINT is however the same. Dos Error 2 As a computer technician, I rely on documentation to guide me through these types of messages.

Possible causes would include a defective disk or faulty drive, although write errors do occur on occasion for no apparent reason. http://sammcallister.com/dos-error/dos-error-40.html DOS 4=Too many files open. ISAM 111=No match was found. Also reported when trying to access a non-existent file. 4 Too many open files The maximum number of files currently opened by your process has been reached. Dos Error 59

UNIX 28=No space left on device. Try resaving the tile onto another disk to see if the error recurs. UNIX 102=Address already in use. his comment is here ISAM 203=Bug msg - no info.

I would be very interested to hear any comments, further information or corrections (I hope there won't be too many of those!) that you may have. Dos Error 64 if False, then runerror 204 is raised. 205 Floating point overflow You are trying to use or produce real numbers that are too large. 206 Floating point underflow You are trying COBOL 9C=No entries left in lock table.

Reported by Read, Readln, Eof, Eoln, SeekEof, or SeekEoln on a text file if the file is not open for input.

COBOL 23=Record not found. DOS 15=Invalid drive number. For a complete discussion of the heap manager, refer to Chapter 15, "Inside Turbo Pascal." Resolutions: Attempt to get more free memory in DOS environment. 204 Invalid pointer operation. Dos Errorlevel No permission to access the file or directory. 6 Invalid file handle If this happens, the file variable you are using is trashed; it indicates that your memory is corrupted. 12

Error 132 will occur if you issue a special command to a device which doesn't have any special commands associated with it. This shouldn't be seen with present day drives, but was apparently a fairly common problem with the early 810s. DOS 0=No error. weblink By default, an underflow causes a result of zero to be returned.

supports two main types of I/O procedure - byte oriented and record oriented. UNIX 87=Attempting to exec a shared library. The incoming byte must be processed before the next can be dealt with, but the peripheral doesn't wait for the computer it sends the next byte regardless. The codes that I am presenting here are from documents I have read through, found on the web, found in old books, documents and technical papers.

ISAM 114=File name too long. UNIX 14=Bad address. Error-144 Device done error. Resolution- Check CONFIG.SYS file for the line Files = ##.

Note: This article was updated on 2016-11-13 and previously published under WIKI_Q210794 Contents 1.What is Dos Cmd Set Errorlevel error? 2.What causes Dos Cmd Set Errorlevel error? 3.How to easily fix UNIX 117=No route to host.